Pumping Well No. | Methods | ||||
Theis | Jacob | Johnson | |||
Hydraulic Conductivity (K) m/s | Transmissivity (T) m2/s | Hydraulic conductivity (K) m/s | Transmissivity (T) m2/s | Specific Yield (Sy) % | |
P.W-1 | 8.68e−06 | 0.001029 | 7.98e−06 | 0.000968 | 0.12 |
P.W-2 | 1.31e−05 | 0.001118 | 1.04e−05 | 0.000888 | 0.085 |
P.W-3 | 2.53e−05 | 0.002539 | 2.24e−05 | 0.002256 | 0.10 |
P.W-4 | 9.95e−06 | 0.000807 | 9.6e−06 | 0.000784 | 0.081 |