Symbol

Description

Value and Units

T1

Temperature of primary coolant flowing upward

576 K

T2

Temperature of primary coolant flowing downward

569 K

T3

Temperature of metal tube of coolant flowing upward

571 K

T4

Temperature of metal tube of coolant flowing downward

565 K

T5

Temperature of recirculated water

535 K

T6

Temperature of water in the mixing region

535 K

Ls

Level of water of mixing region of secondary coolant

3.2 m

xb

Quality of coolant at the end of the boiling region

0.233

Psat

Saturation Pressure of secondary water in boiling region

5.9 MPa