Test | VMA Type SCC | Powder Type SCC | Permissible Limits |
Slump Flow diameter (mm) | 690 | 680 | 650 - 800 |
V-Funnel Time T0 (Sec) | 11.2 | 8.2 | 6 - 12 |
V-Funnel at T5 minute (Sec) | 13.8 | 10.9 | ≤T0 + 3 |
L-Box T20 cm (Sec) | 1.2 | 0.89 | 1 ± 0.5 |
L-Box T40 cm (Sec) | 2.3 | 2.34 | 2 ± 0.5 |
L-Box Blocking Ratio (H2/H1) | 0.8 | 0.86 | 0.8 - 1.0 |