Parameter type | Parameter | Value |
Motor parameters | Rated power (P/kW) | 400 |
Rated phase voltage (Us/V) | 260 | |
Rated phase current (Is/A) | 200 | |
Rated frequency (fe/Hz) | 50 | |
Stator resistance (rs/Ω) | 0.009 | |
Stator leakage (lsl/H) | 6.73 × 10−4 | |
Main inductance (lms/H) | 0.0341 | |
Rotor equivalent resistance (rr/Ω) | 0.0131 | |
Rotor equivalent leakage (lrl/H) | 3.78 × 10−4 | |
Pare of poles (np) | 2 | |
Momentum (J/kg∙m2) | 15.25 | |
Inverter parameters | Dead time (td/µs) | 10 |
Switch frequency (fc/kHz) | 2 | |
DC voltage (V) | 700 | |
DC capacitance (mF) | 27.2 | |
DC filter inductance (mH) | 2 |