Run order | Samples | ||||
A [M] | B [˚C] | C [%] | D [days] | Compressive strength [MPa] | |
1 | 12 | 60 | 95 | 7 | 6.7 |
2 | 8 | 60 | 95 | 7 | 5.0 |
3 | 8 | 60 | 85 | 7 | 7.7 |
4 | 12 | 40 | 95 | 7 | 5.8 |
5 | 8 | 60 | 95 | 28 | 6.4 |
6 | 8 | 40 | 95 | 28 | 5.3 |
7 | 10 | 50 | 90 | 14 | 10.5 |
8 | 10 | 50 | 90 | 14 | 10.0 |
9 | 12 | 60 | 95 | 28 | 9.7 |
10 | 12 | 60 | 85 | 28 | 20.0 |
11 | 8 | 60 | 85 | 28 | 8.2 |
12 | 12 | 40 | 85 | 7 | 7.7 |
13 | 8 | 40 | 85 | 28 | 6.2 |
14 | 8 | 40 | 85 | 7 | 4.2 |
15 | 8 | 40 | 95 | 7 | 2.8 |
16 | 12 | 40 | 95 | 28 | 8.1 |
17 | 12 | 40 | 85 | 28 | 13.4 |
18 | 12 | 60 | 85 | 7 | 11.6 |