Type | Specimens | Num. | fc (MPa) | fp (MPa) | L (mm) | D (mm) | t (mm) | L/D | D/t | ß | Load condition |
| CFP-C14-D70 C | 3 | 14 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | 1.16 | On concrete |
CFP-C14-D70 CT | 3 | 14 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | - | On concrete & tube | |
CFP-C14-D100 C | 3 | 14 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | 2.04 | On concrete | |
CFP-C14-D100 CT | 3 | 14 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | - | On concrete & tube | |
CFP-C14-D150 C | 3 | 14 | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | 1.03 | On concrete | |
CFP-C14-D150 CT | 3 | 14 | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | - | On concrete & tube | |
| CFP-C35-D70 C | 3 | 35 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | 1.16 | On concrete |
CFP-C35-D70 CT | 3 | 35 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | - | On concrete & tube | |
CFP-C35-D100 C | 3 | 35 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | 2.04 | On concrete | |
CFP-C35-D100 CT | 3 | 35 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | - | On concrete & tube | |
CFP-C35-D150 C | 3 | 35 | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | 1.03 | On concrete | |
CFP-C35-D150 CT | 3 | 35 | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | - | On concrete & tube | |
| C14-D70 | 3 | 14 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | 1 | On concrete |
C14-D100 | 3 | 14 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | 1 | On concrete | |
C14-D150 | 3 | 14 | 34.2 | 338 | 150.1 | 3.2 | 2.25 | 46.9 | 1 | On concrete | |
| C35-D70 | 3 | 35 | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | 1 | On concrete |
C35-D100 | 3 | 35 | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | 1 | On concrete | |
C35-D150 | 3 | 35 | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | 1 | On concrete | |
| C0-D70 | 3 | - | 33.4 | 158 | 70.0 | 2.0 | 2.25 | 23.3 | 1 | On tube |
C0-D100 | 3 | - | 34.2 | 225 | 100.0 | 3.0 | 2.25 | 33.3 | 1 | On tube | |
C0-D150 | 3 | - | 34.2 | 338 | 150.1 | 3.0 | 2.25 | 46.9 | 1 | On tube |