Sample

Yield strength (0.7%eul) (mpa)

Tensile strength (mpa)

Percentage elongation after fracture (%)

Numbering

Width × wall thickness × gauge length (mm)

Failed tubing

(portrait)

19 × 6.45 × 50

789

838

20

759

828

21

759

822

22

704

816

20

Mean value

753

826

21

Intact tubing

(portrait)

19 × 6.45 × 50

720

779

23

736

794

24

734

788

25

736

796

24

Mean value

732

789

24

API spec 5ct-2021

758 ~ 828

≥793

≥12

Provisions of supply technical agreement

758 ~ 828

≥793

/