Input | Conventional Brake Test Method | With External Load in Second Winding | ||||
Line Current IL | % Efficiency | Power Factor | Line Current IL | % Efficiency | Power Factor | |
Armature:415 V, 50 Hz, 3-Phase Field: DC 60 V, 0.85 A | 5.0 | 83.1 | 0.74 | 5.0 | 82.7 | 0.77 |
6.0 | 78.0 | 0.75 | 6.0 | 85.5 | 0.95 | |
Armature:415 V, 50 Hz, 3-Phase Field: DC 50 V, 0.72 A | 4.0 | 83.0 | 0.63 | 4.0 | 83.0 | 0.74 |
6.0 | 78.0 | 0.64 | 6.0 | 91.1 | 0.74 | |
Armature:415 V, 50 Hz, 3-Phase Field: DC 40 V, 0.62 A | 3.5 | 55.0 | 0.55 | 3.8 | 77.6 | 0.66 |
6.0 | 75.0 | 0.63 | 6.0 | 80.6 | 0.70 |