Component parameters

Effective volume of MBR/L

Membrane module size/cm

Mean pore size of membrane /μm

effective filtration area of membrane/m2

Membrane flux /L∙(m2∙h)−1

Average aeration head aperture /μm

Suction pump mode

Hydraulic retention time/h

Sludge retention time/d

Dissolved oxygen/(mg∙L−1)

Reactor R1

77

50 × 36 × 52

0.1

0.2

8 - 10

800 - 1500

1 min on and 8 min off

10

20

1, 4

Reactor R2

77

50 × 36 × 52

0.1

0.2

8 - 10

150 - 200

1 min on and 8 min off

10

20

1, 4