System Components

Parameters

Value

PV

Operational Lifetime

25 years

PV derating factor

0.9

Capital cost

$1/W

Replacement cost

$1/W

O & M cost/year

$0.01W

WT

Size

3 kW

Hub height

50 m

Operational lifetime

25 years

Capital cost

$0.6/W

Replacement cost

$0.6/W

O & M cost/year

$0.05/W

Battery

Round trip efficiency

85%

BSOCmin

30%

Vno

6V

Ano

360 Ah

Capital cost

$300/unit

Replacement cost

$300/unit

O & M cost/year

$10

Converter

Efficiency

95%

Operational lifetime

15 years

Capital cost

$0.4/W

Replacement cost

$0.4/W

O & M cost/year

$0.01/W

Diesel Generator

Efficiency

40%

Operational lifetime

2500 h

Capital cost

$0.66/W

Replacement cost

$0.66/W

O & M cost

$0.05/h