Characteristics | Type of certified reference material | ||||
СО ПД(Ф)Р-5/50 | СО ПД(Ф)Э-5/50 | СО ПД(Ф)Р-30/200 | СО ПД(Э)-1/10 | СО ПД (ДТС)-0,05/10 | |
Number of registry, certificate number, expiration date | ГСО 7865-2000, №˚1903, 18.01.2016 | ГСО 7904-2001, №˚2069, 16.09.2016 | ГСО 7903-2001, №˚2068, 16.09.2016 | ГСО 8916-2007, №˚3057, 22.04.2018 | ГСО 9447-2009, №˚4036, 04.12.2019 |
The range of absorbed doses, kGy | 5 … 50 | 5 … 150 | 30 … 200 | 1 … 10 | 0.05 … 10 |
The range of the absorbed dose rate, Gy∙s−1 | 10−1 … 105 | 10−1 … 105 | 10−1 … 105 | 10−1 … 105 | 10−3 … 103 |
The range of radiation energy, MeV |
|
|
|
|
|
for photon radiation | 0.66; 1.25 | 0.66; 1.25 | 0.66; 1.25 | 0.66; 1.25 | 0.66; 1.25 |
for electron radiation | 0.3 … 10 | 0.3 … 10 | 0.3 … 10 | 0.3 … 10 | - |
The boundaries of permissible values of fractional error of appraisal values of validation at P = 0.95% | 7 | 3 | 7 | 7 | 5 (50 - 500 Gy) 7 (1 - 10 kGy) |
Fractional error of measurement of absorbed dose at P = 0.95, not more, % | 12 | 7 | 15 | 15 | 10 (50 - 500 Gy) 15 (1 - 10 kGy) |
The temperature during irradiation, °С | 15 … 40 | 15 … 40 | 15 ... 40 | 15 … 40 | 15 … 40 |
Registering of optical density after irradiation | from 30 minutes to 4 days | from 30 minutes to 4 days | from 30 minutes to 4 days | from 30 minutes to 4 days | after 22 - 26 hours |