Test Water

Residual Chlorine conc.

0.0 - 1.0 mg/L

pH

7.2 ± 0.4 (by CO2 gas: 0.2 mL/min

Water Temperature

25.0˚C ± 10˚C

Electric Conductivity

20.0 - 30.0 mS/m

Raw Water

Service Water (Miyoshi-machi, Iruma-gun, Saitama, Japan)

Circulating Water Volume

8.0 ± 0.5 L/min

Retained Water Volume

11 L

Specimens

Plate

SUS304: 30 × 50 × 8 mmt (Effective area 1.0 cm2)

Pipe

SUS304TPD: φ 13 mm × 150 mmL

Test Duration

30 days

Measurement Items

Immersion Potential

HZ5000 and HE-104A (HOKUTO DENKO)

Residual Chlorine conc.

RM-52-PC-B3 (TACMINA)

AQ-101 (SIBATA SCIENTIFIC TECHNOLOGY)

pH

D-52 (HORIBA)

Electric Conductivity

CM-31P (DKK/TOA)

Water Temperature

D-52, CM-31P

Analysis of Water Quality

2 times (before and after test)

Analysis of Specimens

Microscopic Examination, SEM, EPMA