Light Pollution Reduction

2

18. Confirmation that procedures mitigation of light pollution is matching with local and global standards.

2

Alternative Transportation

2

19. Ensure that the distance between the main project entrance and the nearest public transport station is not more than 400 meters.

2

2

20. Provide a place and equipment for using bicycles at a distance of no more than 200 meters from the entrance to the project.

2

Water Harvesting

1

21. Using rainwater management system during and after storms.

1

2

22. A strategy to collect and treat at least 90% of the water.

2

1

23. Existence of program for maintaining of the storm water management system.

1

20

10

2. Indoor Environment Quality

30 Points-15%

Y

Pre required

Minimum indoor air quality performance

Y

Pre required

Smoking control

Ventilation and Air Quality

1

1. Installing a carbon dioxide level monitor.

1

1

2. Increasing 15% in the rate of ventilation over the rate of forced ventilation.

1

2

3. Using natural ventilation.

2

Hazardous Material

1

4. Ensure that the sticky materials used meet local and international standards.

1

1

5. Confirming that the used paints meet local and international standards.

1

2

6. Confirming that the materials used (Asbestos, Carpet & Hard Flooring, Ceiling Systems and Formaldehyde) meet local and international standards.

2

Car Park Air Quality Management

2

7. Emphasize that the ventilation design of the car park match or exceed the specified level of air pollutant concentration which meet local and international standards. In cases that the project does not contain closed garages with a closing ratio of less than 75%, the points are given automatically.

2

Thermal Comfort

1

8. Confirming on zoning thermal and control devices.

1

2

9. For industrial ventilation: one point when providing a control device for every two people and another point when providing a device (occupancy sensor).

2

2

10. For mixed ventilation: one point when providing windows with manual control for natural ventilation for 50% of the used areas and two points when providing natural ventilation for 75% of the used areas.

2

2

11. Emphasizing the use of thermal modeling calculations during the design process via Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD) accordance with local and international standards.

2

High Frequency Lighting

2

12. Public buildings: All lighting units used meet the local and international standards.

Residential buildings: 95% of the lighting units used meet local and international standards.

2

Daylight and Glare

3

13. Public buildings: achieve at least 250 lux for 75% of used spaces.

Residential buildings: At least 200 lux for 75% of living rooms and bedrooms.

Schools: achieve a minimum of 300 lux for 90% of the spaces used.

3