| Validation parameter | % RSD of peak area in standard solution for five replicate injections (NMT 5.0%) | ||
| 2-hydroxy-5-methylpyridine | Pirfenidone | Iodobenzene | |
| Specificity | 1.84 | 1.54 | 0.85 |
| Determination of LOD & LOQ values | 0.80 | 1.62 | 1.80 |
| Precision at LOQ | 1.28 | 1.31 | 1.93 |
| Linearity study | 1.62 | 2.11 | 1.20 |
| Accuracy | 1.80 | 1.11 | 0.56 |
| System precision | 1.94 | 0.81 | 2.26 |
| Method precision | 1.91 | 1.54 | 2.99 |
| Intermediate precision | 0.52 | 2.92 | 1.83 |
| Robustness study-actual | 1.30 | 1.77 | 1.95 |