Parameter | unit | Value |
Number of cogeneration units |
| 2 |
Net electrical power per unit | MW | 1.1 |
Total annual electricity production | MWh | 8017.2 |
Required thermal power | MWth | 10.5 |
Calorific value of biomass | MJ/kg | 19.8 |
Boiler efficiency | % | 80 |
Biomass consumption | t/year | 19,787 to 39,575 |
Total consumption /h | Kg/h | 2290 to 4680 |
Biomass price envisaged | $ | 55 |