| Condition type | STC | Real condition |
1 | Solar incident angle | Always zero, irradiation beam always normal to the PV panel, (can be achieved in real operation) | Variable, and depends on time, date, and site latitude. In case of roof top system, roof orientation and inclination governs system capacity. |
2 | Solar irradiation | Always equal to 1000 W/m2 (cannot be achieved in real operation) | Variable and depends on the time, date, and site latitude. Limited sun shine hours bound system capacity. |
3 | Ambient temperature | Always 25˚C, (cannot be achieved in real operation) | Variable and depends on the time, date, weather condition and site latitude. Higher ambient temperature degrades PV panel efficiency and reduces system output. |
4 | Air mass Coefficient (AM) | Always equal to 1.5 (cannot be achieved in real operation) | Variable and depends on the time, date, and site latitude. Higher AM with higher latitudes. |
5 | System losses (eg., wiring, inverter) | Always Zero (cannot be achieved in real operation) | Variable and depends on the design and location of PV panels, inverter, and grid meter. |