References | Level of the quality | Score | Observations | |||
A | B | C | D | |||
Architectural standards | + |
|
|
| 4 | Protection against dust, State of the premise good, fence made, accessible location |
Reception and orientation system |
| + |
|
| 3 | Layout of the assistant staff, absence of an orientation sign. |
Structure/ANC equipment |
| + |
|
| 3 | Good quality technical material But incomplete (No portable lamp) |
Equipment of the waiting room | + |
|
|
| 4 | Number of sufficient benches and of good qualities |
Consultation unit of gynecology | + |
|
|
| 4 | Full equipment in the doctor’s consultation room and on call room |
Immediate postpartum assistance unit |
| + |
|
| 3 | 1 room with 2 beds (poor quality mattresses), sufficient space and ventilation (limited capacity) |
Drug supply Architectural standards and cost of drugs |
| + |
|
| 3 | Sufficient protection against dust, lack of air conditioning, accessible medicines |
Functionality laboratory | + |
|
|
| 4 | Functional for the most common biological examinations: rhesus grouping rate Hb, BW, HIV, thick drop |
State of the toilets |
| + |
|
| 3 | Privacy respect insufficient property |
Operating room |
| + |
|
| 3 | Complete technical equipment, lack of adequate resuscitation service (oxygen) |
Supply system in water and waste disposal | + |
|
|
| 4 | Drinking water available within the center, Existence of incinerator; Waste regularly spills for biomedical treatment |
Hospitalization unit |
|
| + |
| 2 | 3 Large rooms with 15 beds, one (1) M.K.C unit (Mother Kangaroo Care) with 4 beds and a dressing room for cesareans. A total of 19 hospital beds, sufficient ventilation, Lack of property and impregnated mosquito net. |
Lighting system and communication | + |
|
|
| 4 | Public network, landline and mobile phone for reception with WIFI internet connection. Functional generator. |