Blow molding pressure (MPa) | Given initial values of iterative time step when the parison is inside the cavity after the first iteration (×10−5 s) | Given initial values of iterative time step when the parison is outside the cavity after the first iteration (×10−5 s) |
0.1 | 8.29 | 8.30 |
0.2 | 5.73 | 5.74 |
0.3 | 4.78 | 4.79 |
0.4 | 4.14 | 4.15 |
0.5 | 3.70 | 3.71 |
0.6 | 3.38 | 3.39 |
0.7 | 3.13 | 3.14 |
0.8 | 2.93 | 2.94 |
0.9 | 2.76 | 2.77 |
1.0 | 2.62 | 2.63 |
1.1 | 2.50 | 2.51 |
1.2 | 2.39 | 2.40 |
1.3 | 2.29 | 2.30 |