| Cement | Lap shear bond strength after 7-cycle tensional stress test, MPa | |
| Without CMF | With CMF | |
| G | Failed after 1 cycle | Failed after 2 cycles |
| CaP | Failed after 3 cycles | 0.31 |
| 60/40 CAC/FAF | Failed after 4 cycles | 0.88 |
| 40/60 CAC/FAF | Failed after 2 cycles | 0.27 |
| 20/80 CAC/FAF | Failed after 1 cycle | Failed after 2 cycles |