| Journal |
Author |
Study Period |
# of Studies |
Results |
Conclusion |
| J. Radiology (2002) |
Muradin, GS [16] |
1993-2000 |
19 |
PTA = 923, Stent = 473. Claudication results depended on lesion type. CLI results were independent of lesion types. Results were similar in both lesion types. |
Funnel plot asymmetrical. Cohort study used for analysis. |
| J. Vasc Intev Radiol (2008) |
YaJun [17] |
1999-2007 |
7 |
PTA and stent placement better 6/12 patency than PTA alone with no difference after this time |
Initial benefit for PTA and stent lost at 6 months |
| J Vasc Surg (2008) |
Mwipatayi [18] |
2000-2007 |
24 |
PTA = 452, stent = 482. Patency no different between the groups. |
At 1 year no difference between groups for patency |
| European Heart Journal (2009) |
Kasapis [19] |
1997-2007 |
10 |
Stent = 274, PTA with provisional stent = 718. Immediate technical failure higher in PTA group. CLI < 10% of patients. |
No difference in TVR. Similar amputation rate. |
| J Vasc Surg (2010) |
Perio [20] |
1997-2007 |
19 |
cohort studies used in analysis |
1-year patency for stent placement or PTA alone no difference. Studies high degree of heterogeneity |
| Cochrane Data Base (2014) |
Chowdhury [21] |
2014 |
11 |
Benefit of PTA and stent lost at 12-months. |
No long-term difference between groups |