Journal | Author | Study Period | # of Studies | Results | Conclusion |
J. Radiology (2002) | Muradin, GS [16] | 1993-2000 | 19 | PTA = 923, Stent = 473. Claudication results depended on lesion type. CLI results were independent of lesion types. Results were similar in both lesion types. | Funnel plot asymmetrical. Cohort study used for analysis. |
J. Vasc Intev Radiol (2008) | YaJun [17] | 1999-2007 | 7 | PTA and stent placement better 6/12 patency than PTA alone with no difference after this time | Initial benefit for PTA and stent lost at 6 months |
J Vasc Surg (2008) | Mwipatayi [18] | 2000-2007 | 24 | PTA = 452, stent = 482. Patency no different between the groups. | At 1 year no difference between groups for patency |
European Heart Journal (2009) | Kasapis [19] | 1997-2007 | 10 | Stent = 274, PTA with provisional stent = 718. Immediate technical failure higher in PTA group. CLI < 10% of patients. | No difference in TVR. Similar amputation rate. |
J Vasc Surg (2010) | Perio [20] | 1997-2007 | 19 | cohort studies used in analysis | 1-year patency for stent placement or PTA alone no difference. Studies high degree of heterogeneity |