Validation criteria | Conc. (µg mL−1) | Artesunate |
Trueness: Absolute bias (µg mL−1) (Relative bias (%)) | 3000.0 | 7.9 (0.3) |
4000.0 | −4.8 (−0.1) | |
5000.0 | 15.0 (0.3) | |
6000.0 | 16.3 (0.3) | |
7000.0 | −42.0 (−0.6) | |
Precision: Repeatability (%)/ Intermediate precision (%) | 3000.0 | 0.3/3.3 |
4000.0 | 0.2/1.3 | |
5000.0 | 0.2/1.1 | |
6000.0 | 0.2/1.1 | |
7000.0 | 0.2/1.4 | |
Accuracy: 95% β-expect. tol. int. (µg mL−1) [Rel. 95% β-expect. tol. int (%)] | 3000.0 | 2680 - 3264 [−9.593, 10.13] |
4000.0 | 3870 - 4174 [−3.9 - 3.7] | |
5000.0 | 4722 - 5084 [−3.4 - 4.0] | |
6000.0 | 5692 - 6060 [−2.9 - 3.4] | |
7000.0 | 6628 - 7211 [−4.8 - 3.6] | |
Linearity: | Slope | 0.9916 |
Intercept | 39.49 | |
R2 | 0.9975 | |
Dosing range: | Lower LOQ (µg mL−1) | 3820 |
Upper LOQ (µg mL−1) | 6962 |