Service

Weighting criteria

Likert scores/Multipliers (w = 1, 2, 3)

Groundwater recharge (G)

Does an underlying aquifer exist to store the water that percolates?

G n w = [ G n × 3 , for major aquifer G n × 2 , for minor aquifer G n × 1 , for no aquifer ] 1,2

(1)

Surface water supply (R)

How many reservoirs (r) are located below the watershed?

R n w = [ R n × 3 , r > 5 R n × 2 , 5 r > 1 R n × 1 , r 1 ]

(2)

Soil retention (S)

The productivity of the soils within the watershed

S n w = [ S n × 3 , for highly productive soils S n × 2 , for moderately productive soils S n × 1 , for low productive soils ]

(3)

Carbon storage (C)

How much carbon (t/ha CO2) is emitted (e) from the watershed?

C n w = [ C n × 3 , e 100000 C n × 2 , 100000 > e > 0 C n × 1 , e = 0 ]

(4)