| BEAM Plus | BREEAM | CIBSE | LEED | Three Stars |
Daylight Factor | 80% area, 1% (1 credit) 95% area, 1% (2 credit) | Different latitude has a different standard | Different function has a different standard | 75% occupied space, 2% | × |
Vertical Daylight Factor | √ | × | × | × | × |
Uniformity |
| ≥0.3, ≥0.7 (atria), or 80% area view sky, and d/w+d/HW < 2/(1-RB) | Task Illuminance: ≥0.7 illuminances of immediate surrounding area: ≥0.5 | × | × |
Annual Illuminance | ≥75%, 100 lux (1 credit) ≥85%, 100 lux (2 credit) | ≥80% area, 200 lux, 2650 hrs (avg.) 60 lux, 2650 hrs (min) | Different function has different standard | × | Refer to GB/t50033 |
View of sky | ≥60%, (1 credit) ≥80%, (2 credit) | 80% area | × | 90% | × |
Unified Glare Rating (UGR) | × | × | Different function has different standard | × | × |
Window to Wall | × | Depends on distance from widow to work space | Depends on the depth of room from outside wall | × | 0.3 ≤ x ≤ 0.4 |