ID

Start

state

Next/End state

Input

Expected output

PQMS2-ACS-INT-TC001

S0

S1-S4-S12

Start the XAve-R program interface, and click the menu item of “Setting—Supervision/Tolerance setting” or toolbar item of “Supervision/Tolerance”, and enter “Supervision/Tolerance” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet, and return the XAve-R interface. Click the button “Shut off” in the up-right corner of the XAve-R interface.

Display “Supervision/Tolerance setting” sheet, and shut off. After return to the idle state, from the XAve-R interface, finally exit program.

PQMS2-ACS-INT-TC002

S0

S2-S4-S12

Enter the XAve-R interface again, and click the menu item of “Setting—Coefficient setting” or toolbar item of “Coefficient”, and enter “Coefficient setting” sheet. Without input, click the button “Cancel” of the sheet, and return the XAve-R interface. Click the button “Shut off” in the up-right corner of the XAve-R interface.

Display “Coefficient setting” sheet, and shut off. After return to the idle state, from the XAve-R interface, finally exit program.

PQMS2-ACS-INT-TC003

S0

S3-S4

Enter the XAve-R interface again, and click the menu item of “Setting—Drawing layout setting” or toolbar item of “Drawing layout”, and enter “Drawing layout setting” sheet. Without input, c lick the button “Cancel” of the sheet., and return the XAve-R interface.

Display “Drawing la-yout setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC004

S4

S1-S4

After the XAve-R program idle interface, click the menu item of “Setting—Supervision /Tolerance setting”, and enter “Supervision /Tolerance” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Display “Supervision /Tolerance setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC005

S4

S2-S4

Enter the XAve-R program idle interface, and click the menu item of “Setting—Coefficient setting”, and enter “Coefficient setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Display “Coefficient setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-C006

S4

S3-S4-S12

Enter the XAve-R program idle interface, and click the menu item of “Setting—Drawing layout setting”, and enter “Drawing layout setting” sheet. Without input, click the button “Shut off” in the up-right corner of “Drawing layout setting” sheet. Click the button “Shut off” in the up-right corner of the XAve-R interface.

Display “Drawing layout setting” sheet, and shut off, then return to the idle state. Finally, Exit XAve-R program.

PQMS2-ACS-INT-TC007

S0

S6

Click the menu item “XAve-R chart monitoring—Monitoring forward” in the XAve-R program interface.

Execute monitoring forward.

PQMS2-ACS-INT-TC008

S6

S7

Click the menu item “XAve-R chart monitoring—Monitoring backward” in the XAve-R program interface.

Execute monitoring backward.

PQMS2-ACS-INT-TC009

S7

S7

Continuously click the toolbar item “Monitoring backward” to the first data batch.

Display again.

PQMS2-ACS-INT-TC010

S7

S9-S4

At the first batch data, click the toolbar item “Monitoring backward”.

Prompt “Returned the first batch data”, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC011

S4

S7

After idle state, click the toolbar item “Monitoring backward”.

Execute monitoring backward.

PQMS2-ACS-INT-TC012

S7

S5

Click the button “Update” in the XAve-R program interface.

Display again.

PQMS2-ACS-INT-TC013

S5

S1-S4

After updating, click the toolbar item “Supervision/Tolerance setting”, and enter “Drawing layout setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Display “Supervision /Tolerance setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC014

S4

S5-S2-S4

Click the button “Update” in the XAve-R program interface. Click the toolbar item “Coefficient setting”, and enter “Coefficient setting” sheet. Without input, click the button “Cancel” of the sheet.

After updating, display “Coefficient setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC015

S4

S5-S3-S4

Click the button “Update” in the XAve-R program interface. Click the toolbar item “Drawing layout setting”, and enter “Drawing layout setting” sheet. Without input, click the button “Cancel” of the sheet.

After updating, display “Drawing layout setting” sheet, and shut off, then return to the idle state.

PQMS2-ACS-INT-TC016

S4

S1-1-S4

After idle state, click the toolbar item “Supervision /Tolerance setting”. In “Supervision /Tolerance setting” sheet, click the button “OK” with default correct input.

Display “Supervision/Tolerance setting” sheet. Save setting, and return to idle state.

PQMS2-ACS-INT-TC017

S4

S2-1-S4

After idle state, click the toolbar item “Coefficient setting”. In “Coefficient setting” sheet, click the button “OK” with default correct input.

Display “Coefficient setting” sheet. Save setting, and return to idle state.

PQMS2-ACS-INT-TC018

S4

S3-1

After idle state, click the toolbar item “Drawing layout setting”. In “Drawing layout setting” sheet, click the button “OK” with default correct input.

Display “Drawing layout setting” sheet. Save setting, and return to idle state.

PQMS2-ACS-INT-TC019

S4

S1-2-S11-S4

After idle state, click the toolbar item “Supervision /Tolerance setting”. In “Supervision /Tolerance setting” sheet, click the button “OK” with null value for all inputs. Click the button “OK” of the prompt dialogue.

Display “Supervision/Tolerance setting” sheet. Prompt message of error input and shut off. Then return to idle state.

PQMS2-ACS-INT-TC020

S4

S2-2-S11-S2-2-S4

After idle state, click the toolbar item “Coefficient setting”. In “Coefficient setting” sheet, click the button “OK” with null value for all inputs. Click the button “OK” of the prompt dialogue. Return “Coefficient setting” sheet, click the button “Shut off” in the up-right corner of sheet.

Display “Coefficient setting” sheet. Prompt message of error input and shut off. Return the sheet, and shut off. Then return to idle state.

PQMS2-ACS-INT-TC021

S4

S3-2-S11-S3-2-S4

After idle state, click the toolbar item “Drawing layout setting”. In “Drawing layout setting” sheet, click the button “OK” with null value for all inputs. Click the button “OK” of the prompt dialogue. Return “Drawing layout setting” sheet, click the button “Shut off” in the up-right corner of sheet.

Display “Drawing layout setting” sheet. Prompt message of error input and shut off. Return the sheet, and shut off. Then return to idle state.

PQMS2-ACS-INT-TC022

S4

S6-S5

Click the toolbar item “Monitoring forward” in the XAve-R program interface. Then click the button “Update”.

Execute monitoring forward, and display again.

PQMS2-ACS-INT-TC023

S5

S6

After updating, click the toolbar item “Monitoring forward”.

Execute monitoring forward.

PQMS2-ACS-INT-TC024

S6

S10-S4

Click the menu item “Print-Preview” in the XAve-R program interface, and enter preview interface. Then shut off.

Preview the chart. Then shut off, return to XAve-R program interface.

PQMS2-ACS-INT-TC025

S4

S5

Click the button “Update” in the XAve-R program interface.

Display again.

PQMS2-ACS-INT-TC026

S5

S10-S4

Click the menu item “Print-Preview” in the XAve-R program interface, and enter preview interface. Then shut off.

Preview the chart. Then shut off, return to XAve-R program interface.

PQMS2-ACS-INT-TC027

S4

S7-S5-S7

Click the toolbar item “Monitoring backward” in the XAve-R program interface, and click the button “Update”. After updating, click the toolbar item “Monitoring backward” again.

Execute monitoring backward. Display again. Execute monitoring backward again.

PQMS2-ACS-INT-TC028

S7

S10-S4

Click the menu item “Print-Preview” in the XAve-R program interface, and enter preview interface. Then shut off.

Preview the chart. Shut off, and return to XAve-R program interface.

PQMS2-ACS-INT-TC029

S4

S5-S10-S4

Click the button “Update” in the XAve-R program interface. Click the menu item “Print-Preview” in the XAve-R program interface, and enter preview interface. Then shut off.

Display again. Preview the chart. Shut off, and return to XAve-R program interface.

PQMS2-ACS-INT-TC030

S4

S12

Click the button “Shut off” in the up-right corner of the XAve-R program interface.

Exit program.

PQMS2-ACS-INT-TC031

S0

S6-S6-S8-S4

Enter the XAve-R program interface again, and continuously click the toolbar item “Monitoring forward” to the last data batch. At the last data batch, click the toolbar item “Monitoring forward” again. Click the button “OK” of the prompt dialogue.

Execute monitoring forward continuously. Prompt “Arrived at the last data batch”. Shut off, and return to idle state.

PQMS2-ACS-INT-TC032

S4

S7-S7-S9-S4

After idle state, continuously click the toolbar item “Monitoring backward” to the first data batch. At the first data batch, click the toolbar item “Monitoring backward” again. Click the button “OK” of the prompt dialogue.

Execute monitoring forward continuously. Prompt “Returned the first data batch”. Shut off, and return to idle state.

PQMS2-ACS-INT-TC033

S4

S10-S4

Click the menu item “Print-Preview” in the XAve-R program interface, and enter preview interface. Then shut off.

Preview the chart. Shut off, and return to XAve-R program interface.

PQMS2-ACS-INT-TC034

S4

S6-S1-S4

Click the toolbar item “Monitoring forward” in the XAve-R program interface. Click the toolbar item “Supervision /Tolerance setting”, and enter “Supervision /Tolerance setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring forward. Then display “Supervision/Tolerance setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC035

S4

S6-S2-S4

Click the toolbar item “Monitoring forward” in the XAve-R program interface. Click the toolbar item “Coefficient setting”, and enter “Coefficient setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring forward. Then display “Coefficient setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC036

S4

S6-S3-S4

Click the toolbar item “Monitoring forward” in the XAve-R program interface. Click the toolbar item “Drawing layout setting”, and enter “Drawing layout setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring forward. Then display “Drawing layout setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC037

S4

S7-S1-S4

After idle state, click the toolbar item “Monitoring backward”. Then click the toolbar item “Supervision/Tolerance setting”, and enter “Supervision /Tolerance setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring backward. Display “Supervision/Tolerance setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC038

S4

S7-S2-S4

After idle state, click the toolbar item “Monitoring backward”. Then click the toolbar item “Coefficient setting”, and enter “Coefficient setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring backward. Display “Coefficient setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC039

S4

S7-S3-S4

After idle state, click the toolbar item “Monitoring backward”. Then click the toolbar item “Drawing layout setting”, and enter “Drawing layout setting” sheet. Without input, click the button “Shut off” in the up-right corner of the sheet.

Execute monitoring backward. Display “Drawing layout setting” sheet. Shut off, and return to idle state.

PQMS2-ACS-INT-TC040

S4

S6

Click the toolbar item “Monitoring forward” in the XAve-R program interface.

Execute monitoring forward.

PQMS2-ACS-INT-TC041

S6

S12

Click the button “Shut off” in the up-right corner of the XAve-R program interface.

Exit program.

PQMS2-ACS-INT-TC042

S0

S6-S7-S12

Enter the XAve-R program interface again, and click the toolbar item “Monitoring forward”. Then click the toolbar item “Monitoring backward”. Finally click the button “Shut off” in the up-right corner of the main program interface .

Start program, execute monitoring forward. Then monitoring backward. Exit program finally.

PQMS2-ACS-INT-TC043

S0

S5-S5-S12

Enter the XAve-R program interface again, and click the toolbar item “Update”, and click it again. Finally Click the button “Shut off” in the up-right corner of the main program interface.

Start program, display again. Then execute update again. Exit program finally.