Parameter

mean value

Extraction method

Comments

1

Rsh

(4.93 ± 0.07) × 104 Ω

Slope of reverse I-V plots

Not temperature dependent

2

n

2.04

lnId-V plots

Temperature (T) dependent

1.65

[dV/d(lnI)]-I plots

Increases with increasing T

3

Rs

0.30 Ω

lnId-V plots

Increases with increasing T

0.56 Ω

[dV/d(lnI)]-I plots

Temperature dependent

0.45 Ω

Cheung’s H-I plots

Temperature dependent

4

Is

1.7 × 10−4 A

lnId-V Plots

Increases with increasing T

0.34 × 10−4 A

Imax-(1/T) plots

----

5

ΦB

0.325 eV

Arrhenius plots

Increases with increasing V

0.198 eV

Cheung’s H-I plots

Decrease with increasing T

6

AA**

2.35 × 10−6 A·K−2

Arrhenius plots

Increases with increasing V

7

ΦB0

0.191 V

V dependence of ΦB

Temperature dependent

8

Vbi

0.496 V

Imax-(1/T) plots

----

9

NA or ND

6.06 × 10+18 cm−3

Reverse I-V-T data

Decreases with increasing T