Electrical Load | N˚ of Units | Operating hours per day | Active Power | Power Factor | Mode | Reactive Power | Apparent Power | Energy Per Day |
TV | 1 | 8 | 250 | 0.95 | AC | 83 | 264 | 2112 |
Lights | 5 | 12 | 15 | 1 | AC | 0 | 15 | 180 |
Refrigerator | 1 | 12 | 200 | 0.7 | AC | 205 | 287 | 3444 |
Laptop | 1 | 4 | 64 | 1 | DC | 0 | 64 | 256 |
Electric iron | 1 | 0.5 | 1000 | 1 | AC | 0 | 1000 | 500 |
Mobile phone | 4 | 8 | 8 | 1 | DC | 0 | 8 | 64 |
TV Decoder | 1 | 8 | 35 | 0.9 | AC | 17 | 39 | 312 |
Moulinex | 1 | 0.05 | 600 | 0.7 | AC | 613 | 858 | 43 |
Security system | 1 | 10 | 2 | 1 | DC | 0 | 2 | 20 |
Standing Fan | 1 | 8 | 100 | 0.75 | AC | 89 | 134 | 1072 |
Total 8003 VAh/Day |