Reference, Year

Animal

Drug

Dose

(mg/Kg)

Concentration

(mg/mL)

Speed

(mL/min)

Infusion time

(min)

Frequency

(Times/d)

Continuous dosing days

(d)

Instrument for controlling speed

Fu (2018) [9]

Japanese white rabbit

VNR

0.5

-

0.5

-

1

2

-

Dan (2015) [12]

Rabbit

VNR

-

-

1.8

5

-

-

-

Wang (2014) [13] a

Rabbit

VNR

12.5/25/50b

1

-

15

1

1

Infusion pump

Kohno (2008) [20] a

Japanese white rabbit

VNR

1.5

0.6/0.3

-

-

1

2

Peristaltic pump

Ge (2017) [1]

Japanese white rabbit

VNR

3

-

5k

30

1

2

-

Wang (2014) [14]

New Zealand rabbit

VNR

5

-

2l

-

-

-

-

Kohno (2009) [21]

Japanese white rabbit

VNR

-

0.6

5k

30

-

2

-

Wang (2014) [14]

C57 Mouse

VNR

37.5

10h

0.75m

-

-

-

-

Zou (2017) [5]

Mouse

VNR

56.25

10

0.25m

-

1

1

-

Shen (2017)

[15] a

C57 Mouse

VNR

18.8/28.1/ 37.5/56.3/75

2.5/5/10

0.15/0.3/0.75m

10

-

7

Bolus pump

Zhang (2016) [6] a

New Zealand rabbit

VCR

0.2

-

0.5

6/12/18/24p

-

-

Infusion pump

Kohno (2009) [21]

Japanese white rabbit

DXR

-

1.4

2k

120

-

3

-

Shen (2017) [9]

New Zealand rabbit

DXR

20b

2

1.5

-

1

3

-

Wang (2015) [22] a

Japanese white rabbit

DXR

-

0.05/0.1/0.2g

0.5/1/1.5

-

-

-

-

Li (2018) [16]

Japanese white rabbit

Mannitol

4d

-

1

-

2

7

-

Zhang (2012) [23]

Japanese white rabbit

Mannitol

2.5d

-

0.5

-

2

2

-

Ge (2014) [24]

New Zealand rabbit

Mannitol

2.5d

-

-

5

1

3

Microinjection pump

Song (2014) [11]

New Zealand rabbit

Mannitol

2.5d

-

8

-

2

5

-

Tang (2017) [25] a

rabbit

Mannitol

2.5d

-

-

-

1

0.5/1/2/3/4

-

Zhang (2016) [26]

New Zealand

rabbit

Mannitol

2.5d

-

-

-

1

5

-