Heat transfer surface of the economizer |
|
| 23.46 | 22.98 | 0.48 |
Total length of tubes of the economizer |
|
| 149.377 | 149.377 | 0 |
Heat of evaporator |
|
| 8716.2764 | 8644.76 | 71.5164 |
Heat transfer surface of evaporator |
|
| 33.281 | 30.678 | 2.603 |
Total length of evaporator |
|
| 211.87 | 211.87 | 0 |
Rate of steam |
|
| 0.7701 | 0.6302 | 0.1399 |
Heat rate of super |
|
| 1179.4 | 1169.98 | 9.42 |
Transfer surface of superheater |
|
| 142.04 | 139.86 | 2.18 |
Mass of dry cherry |
|
| 1350 | 1290.87 | 59.13 |
Moisture in the wet cherry |
|
| 2.3333 | 1.98 | 0.3533 |
Moisture in the dry cherry |
|
| 0.1111 | 0.08956 | 0.02154 |
Water evaporated |
|
| 3000 | 2909.89 | 90.11 |
Inlet gas thermal energy |
|
| 176.982 | 170.68 | 6.302 |
Rate of mass of gas |
|
| 98,684.21 | 98,590.58 | 93.63 |
Heat transfer units in section-III |
|
| 0.022 | 0.002 | 0.020 |
heat transfer units in section-II |
|
| 0.2636 | 0.2333 | 0.0303 |
Total transfer units |
|
| 1.84 | 1.09 | 0.75 |
Diameter of the dryer |
|
| 1.54 | 1.54 | 0 |
Length of dryer |
|
| 9.46 | 9.46 | 0 |
Revolution per min | RPM | peripheral speed / diameter | 4.44 | 4.44 | 0 |
Flue gas loss |
|
| 10.297 | 10.099 | 0.198 |
Other losses |
| By subtraction | 26.9338 | 25.09778 | 1.83602 |
Total heat absorbed in boiler |
|
| 3286.301 | 3198.898 | 87.403 |
Work of feed pump |
|
| 0.9999 | 0.9999 | 0 |
Work of turbine |
|
| 1116.7421 | 1116.7421 | 0 |
Net work |
|
| 1115.742 | 1110.987 | 4.7551 |
Net power output |
|
| 11.2 | 10.97 | 0.23 |
Overall CHP plant efficiency |
|
| 84.15 | 83.957 | 0.193 |