Operation | Volume lost (m3) | Formation strength (kPa/m) |
Lost return when drilling to 2064.5 m with RSS BHA. Topped up annulus with water. | 110 | 11.5 |
Perform wellbore strengthening, squeezed in 29.6 m3 LCM pill. | 26.9 | 11.5 |
Perform second wellbore strengthening, squeezed in 19.7 m3 LCM pill. | 16.2 | 11.5 |
Set cement plug from 2117 m to 1917 m. | 8.2 | 11.75 |
Squeezed in 21 m3 of LCM pill in hesitation mode to record pump off pressure after every 100 litre. | 21 | 11.45 |
Squeezed in 23.5 m3 of LCM pill in hesitation mode to record pump off pressure after every 100 litre. | 23.5 | 11.59 |
Squeezed in 38.5 m3 of LCM pill in hesitation mode to record pump off pressure after every 100 litre. | 38.5 | 11.68 |
Pumped and spot 15 m3 high fluid-loss LCM pill. | 12.3 | 11.64 |
Pumped 30 m3 engineered LCM pill with 335 kg/m3 concentration and fiber. | 20.5 | 12.01 |