| Dosing: poured 120 liters per day (60 liters at 9, 60 liters at 3 p.m.) |
|||||||||||
| DATE/SAMPLING POINT |
t (temperature) |
pH |
TSS |
COD |
BOD5 |
||||||
| ˚C |
|
mg/l |
% |
% |
mg/l |
% |
% |
mg/l |
% |
|
|
| 01.03.2021 (INLET) |
16 |
7.8 |
234 |
|
|
592 |
|
|
380 |
|
|
| Sampling point after primary treatment |
16 |
7.5 |
120 |
|
|
500 |
|
|
170 |
|
|
| 03.03.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
16 |
7.8 |
132 |
|
44 |
452 |
|
24 |
174 |
|
54 |
| EFFLUENT-ITALY |
16 |
7.4 |
90 |
32 |
62 |
368 |
19 |
38 |
82 |
53 |
78 |
| EFFLUENT-AUSTRIA |
16 |
7.5 |
76 |
42 |
67 |
292 |
35 |
51 |
80 |
54 |
79 |
| EFFLUENT-SLOVENIA |
16 |
7.5 |
98 |
26 |
58 |
360 |
20 |
39 |
83 |
52 |
78 |
| Dosing: poured 60 liters per day (in a single dose) |
|||||||||||
|
|
t (temperature) |
pH |
TSS |
COD |
BOD5 |
||||||
|
|
˚C |
|
mg/l |
% |
|
mg/l |
% |
|
mg/l |
% |
|
| 16.03.2021 (INLET) |
17 |
7.9 |
168 |
|
|
416 |
|
|
230 |
|
|
| Sampling point after primary treatment |
16.5 |
7.6 |
154 |
|
|
304 |
|
|
174 |
|
|
| 17.03.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
16 |
7.8 |
128 |
|
24 |
512 |
|
|
335 |
|
|
| EFFLUENT-ITALY |
16.5 |
7.6 |
40 |
69 |
76 |
140 |
73 |
|
104 |
69 |
|
| EFFLUENT-AUSTRIA |
16.5 |
7.4 |
36 |
72 |
79 |
68 |
87 |
|
66 |
80 |
|
| EFFLUENT-SLOVENIA |
16.5 |
7.8 |
78 |
39 |
54 |
108 |
79 |
|
76 |
77 |
|
| Dosing: poured 120 liters per day in three doses (for 8 hours) |
|||||||||||
| 19.03.21 |
t (temperature) |
pH |
TSS |
COD |
|
|
BOD5 |
|
|
||
| INLET |
16.5 |
8.1 |
200 |
|
|
348 |
|
|
325 |
|
|
| Sampling point after primary treatment |
16 |
7.8 |
162 |
|
|
304 |
|
|
172 |
|
|
| 24.03.2021 |
˚C |
pH |
mg/l |
% |
|
mg/l |
% |
|
mg/l |
% |
|
| POOL 2 |
16 |
7.7 |
316 |
|
|
388 |
|
|
335 |
|
|
| EFFLUENT-ITALY |
16 |
7.7 |
48 |
85 |
|
188 |
51.5 |
|
118 |
65 |
|
| EFLUENT-AUSTRIA |
16 |
7.5 |
44 |
86 |
|
136 |
65 |
|
96 |
71 |
|
| EFLUENT-SLOVENIA |
16 |
7.8 |
46 |
85.5 |
|
180 |
54 |
|
138 |
58 |
|
| 26.03.2021 |
16 |
8.2 |
284 |
|
|
384 |
|
|
310 |
|
|
| Dosing: poured 120 liters per day in four doses |
|||||||||||
| 31.03.2021 |
t (temperature) |
pH |
TSS |
|
|
COD |
|
|
BOD5 |
|
|
| POOL 2 |
22 |
7.6 |
220 |
|
|
312 |
|
|
210 |
|
|
| EFFLUENT-ITALY |
21.5 |
7.7 |
40 |
82 |
|
228 |
27 |
|
120 |
43 |
|
| EFFLUENT-AUSTRIA |
21.5 |
7.4 |
48 |
78 |
|
148 |
53 |
|
90 |
57 |
|
| EFFLUENT-SLOVENIA |
22 |
7.7 |
90 |
59 |
|
184 |
41 |
|
118 |
44 |
|
| 07.04.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
17 |
8.2 |
146 |
|
|
324 |
|
|
185 |
|
|
| Sampling point after primary treatment |
16.5 |
7.7 |
122 |
|
|
208 |
|
|
144 |
|
|
| Dosing: poured 60 liters per day in three doses |
|||||||||||
| 08.04.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
18 |
7.9 |
118 |
|
20 |
240 |
|
26 |
150 |
|
|
| EFFLUENT-ITALY |
18 |
7.8 |
86 |
27 |
41 |
132 |
45 |
59.3 |
80 |
47 |
57 |
| EFFLUENT-AUSTRIA |
18 |
7.5 |
70 |
41 |
52 |
128 |
47 |
60.5 |
72 |
52 |
61 |
| EFFLUENT-SLOVENIA |
19 |
7.9 |
88 |
25 |
40 |
136 |
43 |
58 |
60 |
60 |
68 |
| 14.04.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
16 |
8.1 |
188 |
|
|
340 |
|
|
220 |
|
|
| Sampling point after primary treatment |
16 |
7.7 |
122 |
|
|
248 |
|
|
152 |
|
|
| Dosing: poured 150 liters per day in three doses (3 · 50 liters) |
|||||||||||
| 15.04.2021 |
|||||||||||
| POOL 2 |
12 |
7.8 |
160 |
|
|
252 |
|
|
160 |
|
|
| EFLUENT-ITALY |
13 |
7.8 |
86 |
46 |
54 |
120 |
52 |
65 |
72 |
55 |
67 |
| EFLUENT-AUSTRIA |
13 |
7.6 |
52 |
67 |
72 |
104 |
59 |
69 |
56 |
65 |
74 |
| EFLUENT-SLOVENIA |
12 |
7.8 |
80 |
50 |
57 |
136 |
46 |
60 |
70 |
56 |
68 |
| 23.04.2021 |
|||||||||||
| INLET |
16 |
8.2 |
114 |
|
|
320 |
|
|
165 |
|
|
| Sampling point after primary treatment |
16 |
7.7 |
66 |
|
|
180 |
|
|
120 |
|
|
| Dosing: poured 100 liters per day in two doses (2 · 50 liters) |
|||||||||||
| 29.04.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
20 |
7.6 |
110 |
|
|
340 |
|
|
200 |
|
|
| EFLUENT-ITALY |
23.5 |
7.8 |
76 |
31 |
x |
148 |
56 |
X |
90 |
55 |
|
| EFLUENT-AUSTRIA |
23 |
7.7 |
50 |
55 |
x |
180 |
47 |
X |
104 |
48 |
|
| EFLUENT-SLOVENIA |
23 |
7.8 |
70 |
36 |
x |
160 |
53 |
x |
100 |
50 |
|
| 11.05.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
19 |
8.2 |
212 |
|
|
460 |
|
|
268 |
|
|
| Sampling point after primary treatment |
19 |
7.7 |
110 |
|
|
340 |
|
|
178 |
|
|
| 12.05.2021 |
|
|
|
|
|
|
|
|
|
|
|
| Sampling point after primary treatment |
21 |
7.7 |
122 |
|
|
300 |
|
|
150 |
|
|
| POOL 2 |
|
|
|
|
|
|
|
|
|
|
|
| EFLUENT-ITALY |
21 |
7.8 |
84 |
31 |
60 |
112 |
63 |
76 |
50 |
67 |
81 |
| EFLUENT-AUSTRIA |
20 |
7.4 |
58 |
52 |
73 |
160 |
47 |
65 |
78 |
48 |
71 |
| EFLUENT-SLOVENIA |
21 |
7.6 |
78 |
36 |
63 |
140 |
53 |
70 |
82 |
45 |
69.4 |
| 25.05.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
19 |
8 |
152 |
|
|
380 |
|
|
240 |
|
|
| Sampling point after primary treatment |
19 |
7.7 |
118 |
|
|
216 |
|
|
145 |
|
|
| 27.05.2021 |
|||||||||||
| Dosing: (poured 100 - 150 L) |
|||||||||||
| POOL 2 |
23 |
6.9 |
130 |
|
|
300 |
|
|
140 |
|
|
| EFLUENT-ITALY |
24 |
6.9 |
104 |
20 |
32 |
100 |
67 |
74 |
52 |
63 |
78 |
| EFLUENT-AUSTRIA |
24 |
6.9 |
38 |
71 |
75 |
60 |
80 |
84 |
34 |
76 |
86 |
| EFLUENT-SLOVENIA |
24.5 |
6.9 |
24 |
82 |
84 |
120 |
60 |
68 |
54 |
61 |
77.5 |
| 10.06.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
22 |
8.3 |
174 |
|
|
560 |
|
|
260 |
|
|
| Sampling point after primary treatment |
22 |
8 |
98 |
|
|
464 |
|
|
164 |
|
|
| 11.06.2021 |
|
|
|
|
|
|
|
|
|
|
|
| Dosing: (poured 150 L) |
|||||||||||
| POOL 2 |
25.5 |
7.9 |
76 |
|
|
372 |
|
|
200 |
|
|
| EFLUENT-ITALY |
26 |
8.2 |
68 |
10 |
61 |
60 |
84 |
89 |
34 |
83 |
87 |
| EFLUENT-AUSTRIA |
26 |
8.0 |
40 |
47 |
77 |
40 |
89 |
93 |
38 |
81 |
85 |
| EFLUENT-SLOVENIA |
26 |
7.9 |
10 |
87 |
94 |
112 |
70 |
80 |
92 |
54 |
65 |
| 22.06.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
21 |
8 |
158 |
|
|
340 |
|
|
222 |
|
|
| Sampling point after primary treatment |
21 |
7.8 |
100 |
|
|
220 |
|
|
144 |
|
|
| 23.06.2021 |
|
|
|
|
|
|
|
|
|
|
|
| Dosing: poured 200 l per day in three doses |
|||||||||||
| POOL 2 |
26 |
7.9 |
92 |
|
|
280 |
|
|
195 |
|
|
| EFLUENT-ITALY |
26.5 |
8.3 |
52 |
43 |
67 |
148 |
47 |
56 |
56 |
71 |
75 |
| EFLUENT-AUSTRIA |
27 |
8.0 |
36 |
61 |
77 |
120 |
57 |
65 |
36 |
82 |
84 |
| EFLUENT-SLOVENIA |
27 |
7.9 |
18 |
80 |
89 |
180 |
36 |
47 |
94 |
52 |
58 |
| 15.07.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
22 |
8.1 |
220 |
|
|
300 |
|
|
215 |
|
|
| Sampling point after primary treatment |
22.5 |
7.8 |
150 |
|
|
160 |
|
|
132 |
|
|
| 16.07.2021 |
|
|
|
|
|
|
|
|
|
|
|
| Dosing: (poured 100 - 150 L) |
|||||||||||
| POOL 2 |
26 |
8.1 |
106 |
|
|
160 |
|
|
100 |
|
|
| EFLUENT-ITALY |
27 |
8.0 |
74 |
30 |
66 |
60 |
63 |
80 |
44 |
56 |
80 |
| EFLUENT-AUSTRIA |
27 |
7.9 |
94 |
11 |
57 |
140 |
12 |
53 |
86 |
14 |
60 |
| EFLUENT-SLOVENIA |
28 |
7.9 |
36 |
66 |
84 |
40 |
75 |
87 |
32 |
68 |
85 |
| 27.07.2021 |
|||||||||||
| INLET |
22 |
7.9 |
146 |
|
|
360 |
|
|
230 |
|
|
| Sampling point after primary treatment |
22 |
7.7 |
92 |
|
|
260 |
|
|
142 |
|
|
| Dosing: (poured 100 - 150 L) |
|||||||||||
| 28.07.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
24 |
8.0 |
130 |
|
|
216 |
|
|
185 |
|
|
| EFLUENT-ITALY |
24 |
8.2 |
118 |
9.3 |
19.2 |
60 |
72 |
83 |
44 |
76 |
81 |
| EFLUENT-AUSTRIA |
24.5 |
8.1 |
90 |
31 |
38 |
180 |
17 |
50 |
170 |
8 |
26 |
| EFLUENT-SLOVENIA |
24.5 |
7.9 |
42 |
68 |
71 |
140 |
35 |
61 |
132 |
29 |
43 |
| 11.08.2021 |
|
|
|
|
|
|
|
|
|
|
|
| INLET |
22.5 |
7.2 |
104 |
|
|
356 |
|
|
260 |
|
|
| Sampling point after primary treatment |
22.5 |
7.8 |
70 |
|
|
236 |
|
|
156 |
|
|
| Dosing: (poured 100 - 150 L) |
|||||||||||
| 12.08.2021 |
|
|
|
|
|
|
|
|
|
|
|
| POOL 2 |
22.5 |
7.3 |
44 |
|
|
168 |
|
|
135 |
|
|
| EFLUENT-ITALY |
22.5 |
7.8 |
30 |
32 |
71 |
96 |
43 |
73 |
76 |
44 |
71 |
| EFLUENT-AUSTRIA |
23 |
7.7 |
146 |
/ |
/ |
172 |
/ |
52 |
160 |
/ |
39 |
| EFLUENT-SLOVENIA |
22.5 |
7.7 |
78 |
/ |
25 |
140 |
17 |
61 |
130 |
4 |
50 |