Condition

(y = 0.5)

Methane conversion (%)

Thermochemical energy storage

efficiency (%)

Experiment

Simulation

Relative error

Experiment

Simulation

Relative error

qc = 702 kW/m2,

F = 3 L/min

30.9

30.0

-2.90

4.02

3.69

8.15

qc = 714 kW/m2,

F = 4 L/min

36.2

38.3

5.81

5.74

6.10

-6.34

qc = 678 kW/m2,

F = 6 L/min

40.5

43.5

7.29

10.1

10.9

-7.66