Input variable | Specified value | Range |
Fuel composition | Hydrogen 99.9992% (V) | - |
Oxidant composition | Oxygen 99.995% (V) | - |
Fuel cell temperature | 75˚C | ±5˚C |
Temperature of fuel gas at cell inlet | 85˚C | ±10˚C |
Temperature of oxidant gas at cell inlet | 80˚C | ±5˚C |
Pressure at fuel gas line | 1 atm |
|
Pressure at oxidant gas line | 1 atm |
|
Fuel gas flow rate | 300 mL·min−1 | ±100 mL·min−1 |
Oxidant gas flow rate | 200 mL·min−1 | ±15 mL·min−1 |
Relative humidity of fuel gas | 100% | - |