| Parameter | Value | Parameter | Value |
| SOFC current density/A/m2 | 2393.9 | SOFC operating voltage/V | 0.714 |
| SOFC operating temperature/K | 1173 | SOFC electrical power/kW | 1510.15 |
| After burner temperature/K | 1273 | SOFC electrical efficiency/% | 53.74 |
| Fuel compressor power/kW | 33.03 | GT power/kW | 1016.41 |
| Air compressor power/kW | 537.06 | AT power/kW | 139.88 |
| High-pressure pump power/kW | 2.61 | ST power/kW | 105.34 |
| Low-pressure pump power/kW | 0.34 | Input exergy/kW | 2908.36 |
| Total net power of the proposed system/kW | 2092.076 | Total net power of the reference system/kW | 2008.858 |
| Total electrical efficiency of the proposed system/% | 74.414 | Total electrical efficiency of the reference system/% | 71.454 |
| Total exergy efficiency of the proposed system/% | 71.933 | Total exergy efficiency of the reference system/% | 69.072 |