S/No.

Parameter

Value

Unit

1

Pipe length Multiplier

1.5

2

Valve type

Conventional

3

Flare tip diameter

406.4

Mm

4

Knock out drum size

2200

Mm

5

Vapour velocity

18.29

m/s

6

Liquid Velocity

4.57

m/s

7

C 7 + Normal boiling point

110

˚C

8

Mach No

0.7 & 0.5 for tail & header pipes

9

Noise level

85/115

Db

10

RhoV2

6000

kg/ms−2

11

Pipe schedule

40