| Parameter | Value |
| Evaporator duty (kJ/h) | 7,799,004 |
| Overall coefficient of heat | 2495.00 |
| Transfer (kJ/h-m2-C) |
|
| Area of heat transfer (m2) | 288.00 |
| Number of tubes | 764.00 |
| Tube internal diameter (mm) | 16.00 |
| Tube external diameter (mm) | 20.00 |
| Tube length (m) | 6.00 |
| Tube thickness (mm) | 2.00 |
| Number of shell passes | 1 |
| Number of tube passes | 2 |
| Shell diameter (mm) | 774mm |
| Tube layout angle | Triangular (30 degrees) |
| Tube pitch (mm) | 25.00 |
| Baffle spacing (mm) | 309.00 |
| Tube side inlet temperature (˚C) | 31.48˚C |
| Tube side outlet temperature (˚C) | 15.00˚C |
| Tube side pressure (kPa) | 350.00 |
| Shell side pressure (kPa) | 421.2 |
| Water flow rate (m3/h) | 120.0 |
| Refrigerant flow rate (m3/h) | 42.1 |
| Material for tube construction | Copper |