Experiment No. | Temperature (˚C) | Cooling rate (˚C/s) | Soak time before quench (s) |
1 | 970 | 5 | 0 |
2 | 970 | 5 | 10 |
3 | 970 | 50 | 0 |
4 | 970 | 50 | 10 |
5 | 950 | 5 | 0 |
6 | 950 | 5 | 10 |
7 | 950 | 5 | 20 |
8 | 910 | 5 | 0 |
9 | 910 | 5 | 10 |
10 | 910 | 5 | 20 |
11 | 910 | 25 | 0 |
12 | 910 | 25 | 10 |
13 | 910 | 25 | 20 |
14 | 910 | 50 | 0 |
15 | 910 | 50 | 10 |
16 | 910 | 50 | 20 |