Sample Code | Cone Calorimetry Test | |||||
Time to Ignition (s) | Time to Flame Out (s) | Peak HRR (KW/m2) | Total Heat Release (MJ/m2) | Total Smoke Release (m2/m2) | MAHRE (KW/m2) | |
Control | 48 ± 2 | 137 ± 2 | 322 ± 12 | 27 ± 5 | 620 ± 10 | 103 ± 5 |
F-5 | 47 ± 2 | 166 ± 2 | 293 ± 11 | 21 ± 4 | 622 ± 11 | 77 ± 6 |
F-10 | 49 ± 1 | 155 ± 2 | 260 ± 9 | 17± 2 | 354 ± 8 | 66 ± 7 |
C-5 | 60 ± 2 | 85 ± 2 | 157 ± 8 | 9 ± 1 | 1000 ± 12 | 45 ± 4 |
C-10 | 65 ± 1 | 90 ± 2 | 103 ± 9 | 7 ± 1 | 838 ± 8 | 33 ± 5 |