| Time, s | Event |
| 0 | RCP #3 is switched off |
| 2 | Control rod bank #7 drops into the core within 4 s |
| 3 | PZR heater (Group #1) is on |
| 10 | Bank #12 moves in at a rate of 2 cm/s |
| 13 | PZR heaters (Group #3, 4) are on |
| 23 | Reverse flow from cold leg to hot leg of loop #3 started |
| 35 | Temperature in hot leg #3 decreases lower than cold leg |
| 55 | Mass flow rate through reactor core reaches steady state |
| 285 | PZR heaters (Group #3, 4) are off |
| 350 | PZR water level and core pressure are stabilized |
| 420 | End of transient |