Parameter | VVER1200 Simulator | Ninh Thuan Project [8] | NNPP-2 PSAR [9] |
Reactor thermal power, MW | 3212 | 3212 | 3200 + 128 |
Nominal electric power, MW | 1178 - 1183 | 1186 | 1198 |
Reactor Outlet pressure, MPa | 15.9 ÷ 16.1 | 16.2 ± 0.3 | 16.2 ± 0.3 |
Reactor coolant flow rate, m3/h | 86,333 ± 5 | 88,000 (+2100 − 3100) | 86,000 ± 2900 |
Reactor coolant inlet temperature, ˚C | 297.6 | 298.2 +2/−4 | 298.2 +2/−4 |
Reactor coolant outlet temperature, ˚C | 328.8 | 328.6 ± 4 | 328.9 ± 5 |
Reactor heat up, ˚C | 30.5 | 30.7 | 30.7 |
Pressurizer level, m | 8.13 ± 0.01 | 8.17 ± 0.15 | 8.17 ± 0.15 |
SG water level, m | 2.7 ± 0.01 | 2.7 ± 0.05 | 2.7 ± 0.05 |
SG steam pressure, MPa | 7.0 ± 0.02 | 7.0 ± 0.1 | 7.0 ± 0.1 |
Feed water temperature, ˚C | 226.8 ± 0.15 | 225 ± 5 | 225 ± 5 |
Feed water flow in SG1/2/3/4, t/h | 1614 ÷ 1668 | 1602 (+112) | 1602 (+112) |
Operation at load of (% Nnom): - 4 RCPs - 3 RCPs - 2 RCPs (opposite) - 2 RCPs (adjacent) | 100% 66% 49.5% 40% | 100% 67% 50% 40% | 100% 67% 50% 40% |