ID | Start state | End state | Input | Expected output |
PQMS2-MCS-UNI-TC001 | S0 | S1 | Click the menu item of “Setting-Coefficient Setting” or toolbar item “Coefficient Setting” | Display the sheet “setting coefficient of Median chart” |
PQMS2-MCS-UNI-TC002 | S1 | S4 | No input operation, click the button “Cancel” or “Shut off” in the right-up angle | Cancel setting |
PQMS2-MCS-UNI-TC003 | S1 | S2 | Input data in the sheet | Display data in the sheet |
PQMS2-MCS-UNI-TC004 | S2 | S4 | Keep default data and click the button “Save Setting” | Save Setting data and no error information prompt |
PQMS2-MCS-UNI-TC005 | S2 | S3 | Keep blank in all “Input controls” and click the button “Save Setting” | Display error information prompt |
PQMS2-MCS-UNI-TC006 | S3 | S4 | Click the confirming button of dialogue or button “Shut off” in the right-up angle of dialogue | The idle state |
PQMS2-MCS-UNI-TC007 | S2 | S4 | When input data, click the button “Cancel” or “Shut off” in the right-up angle of sheet | Cancel setting |
PQMS2-MCS-UNI-TC008 | S4 | S5 | Click “Shut off” in the right-up angle of sheet | Exit |