| Activation potential | 0.07 V |
| Ohmic potential | 0.22 V |
| Concentration potential | 0.10 V |
| Cell operating voltage | 0.7 V |
| SOFC electrical power | 6640 kW |
| Compressor power | −2260 kW |
| Steam turbine pump power | −0.78 kW |
| Steam turbine power | 1927 kW |
| Gas turbine power | 6740 kW |
| ORC turbine power | 85.7 kW |
| ORC pump power | −0.21 kW |
| Efficiency of system cycle | 65.6% |