Design Point Parameter

Values

Fuel heating value, LHV (MJ/kg)

49.7365

Ambient pressure (kPa)

101.325

Pressure ratio

18.2

Ambient temperature (K)

288.15

Turbine entry temperature, TET (K)

1420

Turbine speed [rpm]

3000

Mass flow (kg)

650

Ambient Relative humidity (%)

60

Shaft power produced (MW)

202.11

Specific fuel consumption (kg/kWh)

0.19

Fuel flow (kg/s)

10.76

Exhaust gas temperature (K)

754.68

Exhaust gas (kg/s)

653.03

Thermal efficiency (%)

38.4