Parameter

Value

Annual electricity use in all sectors except hot water production

213,600 KWhel

Annual requirements for hot water production

71,200 KWhth

Annual electricity requirements for hot water production

14,240 KWhel

Annual heat generation by the solar thermal system

56,960 KWhth

Total annual electricity requirements

227,840 KWhel

Size of a solar-PV system

151.9 KWp

Size of a solar thermal system-area of flat plate collectors

113.9 M2

Capital cost of the solar-PV system

182,280?o:p>

Capital cost of the solar thermal system

34,170?o:p>

Capital cost of both solar energy systems

216,450?o:p>

Overall capital cost per offender

1216?o:p>

Annual carbon emissions due to heating oil use1

19.225 tn CO2

Annual carbon emissions due to grid electricity use2

128.165 tn CO2

Annual total carbon emissions due to conventional fuel use

147.385 tn CO2

Overall annual carbon emissions per offender due to conventional fuel use

0.83 tn CO2

Area of an olive tree plantation sequestrating all carbon emissions3

14.74 ha

Area of a Eucalyptus tree plantation sequestrating all carbon emissions4

5.9 ha