Sensing material | Detection potential (V) | L. R. (M) | D. L. (M) | Stability |
Ag-DNA/GCE | −0.45 | 2.0 × 10−6 - 2.5 × 10−3 | 6.0 × 10−7 |
|
AgPs-SWCNT electrode | −0.3 | 1.6 × 10−5 - 1.8 × 10−2 | 2.76 × 10−6 | 89.92% (30 days) |
Ag NPs/ZnO/GCE | −0.25 | 2.0 × 10−6 - 5.5 × 10−3 | 4.2 × 10−7 |
|
Ag NPs/CHIT-GO/ cysteamine/Au | −0.4 | 6.0 × 10−6 - 1.8 × 10−2 | 7.0 × 10−7 | 98.8% (30 days) |
AgNPs/PoPD/ GCE | −0.5 | 6.0 × 10−6 - 6.73 × 10−2 | 1.5 × 10−6 | 98.2% (15 days) |
Ag NPs/ATP/GCE | −0.3 | 1.0 × 10−5 - 2.15 × 10−2 | 2.4 × 10−6 | no change (2 weeks) |
Ag/GC electrode | −0.44 | 4.0 × 10−5 - 9.0 × 10−1 | 1.0 × 10−5 | 95% (100 days) |
PQ11-AgNPs/GCE | −0.30 | 1.0 × 10−4 - 1.8 × 10−1 | 3.39 × 10−5 |
|
Ag/GN-R/GCE | −0.40 | 1.0 × 10−4 - 4.0 × 10−2 | 2.8 × 10−5 |
|
Ag@PMPD-Ag/GCE | −0.30 | 1.0 × 10−4 - 1.7 × 10−1 | 2.5 × 10−6 |
|
SWCNT/AgNPs/CCE | −0.20 | 1.0 × 10−5 - 8.0 × 10−3 | 2 × 10−7 |
|
Ag-3D/graphite electrode | 0.6 | 5.0 × 10−5 - 2.5 × 10−3 | 1.0 × 10−6 | 92% (30 days) |
Polydopamine-Ag hollow/GCE | −0.30 | 9.2 × 10−5 - 2.0 × 10−2 | 1.97 × 10−6 | 90% (10 days) |
Ag/graphene/GCE | −0.3 | 1.0 × 10−4 - 1.0 × 10−1 | 5.0 × 10−7 |