Initial Properties

PVDF

ECTFE

PPSU

PSU

PEX-b

PA12

E-Modulus [Mpa]

2027

1645

2000

2200

920

1035

Tensile Strength [Mpa]

56.9

31.9

78.8

79.6

26.6

38.1

Elongation at yield [%]

7

6.5

6.5

6.5

6

8.5

Changes in properties after ageing

E-Modulus [Mpa]

−6

−4

0

0

−7

−33

Tensile Strength [Mpa]

4

8

−2

0

−1

−9

Elongation at yield [%]

11

4

−3

−16

6

96