Parameter

Description

Value

V lagoon_storage

storage capacity of the lagoon (days)

35

HRT

hydraulic retention time (days)

20

n

number of livestock

500 cows

n day m

number of days in a month

varies

P rated

rating of the induction machine (hp)

150

L H V propane

lower heating value of propane (kJ/kg)

46,300 [30]

T water

water temperature (˚C)

35

η HEX

heat exchanger efficiency (%)

70

η rated

boiler efficiency (%)

70

c lagoon

unit cost of lagoon (USD/m3)

2.47 [31]

c propane

unit cost of propane (USD/m+)

1.98 [32]

c incentive

unit cost of incentives (USD/kWh)

0.07 [33]

n rand_div

consecutive random moves (diversification Strategy D1)

5

n nonimprov_div

consecutive non-improving moves to apply diversification

5

n restart_div

restarts with incumbent solution (diversification Strategy D2)

3

max_­iter­_div

number of iterations for application of diversification

100

δ h

allowance for heat demand constraint (kW)

10

max­_iter

number of iterations for the stopping condition

150

max_iter_opt

number of iterations for the minimisation of cost

50

max_iter_feas

number of iterations for the minimisation of infeasibility

25

max_iter_div

number of iterations for the application of diversification

100 (cows data)

S infeas

threshold of infeasibility

Varies

S 0 infeas

initial threshold of infeasibility

varies