No | Manufacturer/Model | Table Column Head | |||||||
Rated power (kW) | Rotor diameter (m) | Swept area (m2) | Power density (m2/kW) | Max speed (rad/min) | Cut-in (m/s) | Rated (m/s) | Cut-off (m/s) | ||
1 | Aeronautica Windpower 29 - 225 | 225 | 29 | 660.5 | 2.94 | 37.9 | 2 | 14 | 23 |
2 | Aeronautica Windpower 33 - 225 | 225 | 33 | 855.3 | 3.8 | 33 | 2 | 12 | 23 |
3 | Dewind D4-600 | 600 | 48 | 1809.6 | 3.02 | 29.2 | 2.5 | 12 | 19 |
4 | Enercon E30/200 | 200 | 30 | 706.9 | 3.53 | 48 | 2.5 | 13 | 25 |
5 | Enercon E33/330 | 330 | 33.4 | 876.2 | 2.66 | 39 | 2.5 | 13 | 28 |
6 | Enercon E40/500 | 500 | 40 | 1256.6 | 2.51 | 34 | 2.5 | 13.5 | 25 |
7 | Enercon E40/600 | 600 | 40 | 1256.6 | 2.09 | 34.5 | 2.5 | 13 | 25 |
8 | Soyut Wind 500 | 500 | 39.2 | 1206.9 | 2.41 | NA | 1.5 | 12.5 | 24.5 |
9 | Soyut Wind 250 | 250 | 41.5 | 1333.2 | 5.33 | NA | 1.5 | 12 | 28 |
10 | Soyut Wind 200 | 200 | 36.8 | 1063.6 | 5.32 | NA | 1.5 | 12.5 | 28 |
11 | Soyut Wind 100 | 100 | 26 | 530.9 | 5.31 | NA | 1.5 | 11.5 | 26.5 |
12 | Nordex N27/150 | 150 | 27 | 572.6 | 3.82 | 36 | 3 | 13 | 25 |
13 | Nordex N27/250 | 250 | 27 | 572.6 | 2.29 | 40 | 4 | 16 | 16.5 |
14 | SouthWest Air X | 0.40 | 1.17 | 1.07 | NA | 0 | 3.6 | 12.5 | 26 |
15 | SouthWest Skystream 3.7 | 2.60 | 3.72 | 10.87 | NA | 50 - 330 | 3.5 | 13 | 20 |