Characteristic | Brest-300 | Brest-1200 |
Thermal power, MW | 700 | 2800 |
Electrical power, MW | 300 | 1200 |
Number of fuel assemblies in the reactor core, pcs. | 185 | 332 |
Reactor core diameter, mm | 2300 | 4755 |
Reactor core height, mm | 1100 | 1100 |
Fuel element diameter, mm | 9.1; 9.6; 10.4 | 9.1; 9.6; 10.4 |
Fuel element pitch, mm | 13.6 | 13.6 |
Reactor core fuel | UN + PuN | UN + PuN |
Fuel element column, (U + Pu)N, t | 16 | 63.9 |
Fuel element column, Pu/(Pu239 + Pu241), t | 2.1/1.5 | 8.56/6.06 |
Fuel-element lifetime, years | 5 | 5-6 |
Reloading interval, years | 1 | 1 |
KVA | ~1 | ~1 |
Power effect, % DK/K | 0.16 | 0.15 |
Entire effect, % DK/K | 0.35 | 0.31 |
Delayed neutron fraction, beff % | 0.36 | 0.34 |
Lead in/out temperature, ˚С | 420/540 | 420/540 |
Maximum temperature of fuel element cladding, ˚С | 650 | 650 |
Maximum lead flow rate, m/s | 1.8 | 1.7 |
Steam temperature at the steam generator outlet, ˚С | 340/520 | 340/520 |
Steam generator output pressure, MPa | 24.5 | 24.5 |
Lead flow, t/s | 40 | 158.4 |
Steam generator capacity, t/s | 0.43 | 1.72 |
Net efficiency of power-generating unit, % | 43 | 43 |
Expected useful life, years | 30 | 60 |