No.

Parameters

Value

1

Installed thermal power, MW

280*

2

Power plant electrical output, MW

100

3

Lead-bismuth coolant temperature, ˚C

· at the outlet from the reactor core

· at the inlet to the reactor core

490

340

4

Reactor core dimensions D × Н, m

1.645 × 0.9

5

Reactor core mean volumetric power density, kW/dm3

140*

6

Mean linear load on nuclear fuel elements, kW/m

~24.3*

7

Fuel:

· type

· uranium-235 charging, %

· mean uranium-235 enrichment, %

UO2

~1470*

~16.1*

8

Reactor core service life, thous. eff. hours

~53

9

Reloading interval, years

~8 (~10)

10

Volume of lead-bismuth coolant in circuit, м3

18

11

Reactor shell overall dimensions, m

¯ 4.53 × 6.92

12

Primary circuit coolant, volume m3

Pb-Bi, 32

13

Number of loops

4