| Parameter | Formula to be used | Computed parameters |
| Required Daily Energy Demand: Erd |
| 10.463 kWh/day |
| Average peak power: Pave,Peak |
| 2092.6 W |
| Total Dc current: Idc |
| 87.19 A |
| Number of series modules: Nsm |
| 1 |
| Number of parallel modules: Npm |
| 17 |
| Total number of modules: Ntm |
| 17 |
| Total cost of the array | Array cost × Module cost | US$ 6375.00 |